Accessibility Links

Skip to main content Accessibility help
Accessibility feedback
Lunar New Year 2026
Lunar New Year 2026
Go to Google home
Press / to jump to the search box
Choose what you’re giving feedback on
  • Delete

  • See more
  • Delete

  • See more
  • Report inappropriate predictions
    Quick Settings
    Sign in

    Filters and Topics

    AI Mode
    All
    Images
    Videos
    Shopping
    Short videos
    Forums
    More
    News
    Web
    Books
    Maps
    Tools
    Any time
    Any time
    Past hour
    Past 24 hours
    Past week
    Past month
    Past year
    Custom range...
    Custom date range
    Go
    All results
    All results
    Verbatim
    Advanced Search
    About 6,800 results (0.30s)
    Ctrl+Shift+X to select

    Search Results

    Including results for calibration techniques for fog imu
    Search only for calibration techniques for fog imus

    AI Overview

    An AI Overview is not available for this search Can't generate an AI overview right now. Try again later.
    AI Overview
    Calibration techniques for Fiber Optic Gyroscope (FOG) Inertial Measurement Units (IMUs) focus on determining and compensating for errors in the gyroscopes and accelerometers, such as bias drift, scale factor, and axis non-orthogonality. Given their high-precision nature, FOG IMUs often require
    precise, temperature-controlled, multi-position, or rotational calibration methods .
    Here are the key calibration techniques for FOG IMUs based on recent search results:
    1. Turntable-Based Calibration Methods
    These are the standard, high-precision methods often used for factory calibration.
    • Static Multi-Position Calibration: The FOG IMU is placed in various orientations (e.g., 12-position method) to determine accelerometer and gyroscope biases and scale factors by comparing against Earth’s gravity and rotation.
    • Single-Axis/Multi-Axis Continuous Rotation: The IMU is rotated on a turntable at specific rates (e.g., 10°/s, 30°/s) to excite and calibrate scale factors, non-linear errors, and installation errors.
    • Hybrid Grading Calibration: Combines a coarse calibration (using a low-cost turntable to identify major parameters) with a fine calibration (using a 27-dimension Kalman filter to estimate residual errors).
    • Time Asynchronous Parameter Calibration: A specific method to identify time synchronization errors between the FOG-IMU and the turntable, particularly using single-axis rotations around the X and Y axes.
    2. Environmental & Temperature Calibration
    FOG performance is heavily influenced by temperature.
    • Full-Temperature Calibration: Calibration experiments are performed at multiple temperature points (e.g., -10°C to 40°C) to map the temperature-dependent drift and scale factor of the inertial devices.
    • Segmented Linear Interpolation Compensation: The calibration parameters are updated in real-time based on the temperature, using piecewise linear methods to balance accuracy and computational load.
    3. Advanced & System-Level Calibration
    • Kalman Filter-Based Estimation: An Extended Kalman Filter (EKF) is used, often during initial alignment or in-field operation, to estimate and compensate for IMU errors.
    • System-Level In-Field Calibration: Methods that utilize in-field maneuvering or, in the case of MWD (Measurement While Drilling) systems, use specialized algorithms to reduce the need for bulky, expensive turntables while still providing high accuracy.
    • Lever-Arm Effect Compensation: For FOG-based inertial navigation systems, calibration also includes accounting for the distance between the center of rotation and the IMU, known as the "lever-arm" effect.
    Summary of Key Parameters Calibrated
    • Gyros: Constant drift, temperature-dependent drift, scale factor, and non-linear scale factor errors.
    • Accelerometers: Bias, scale factor, and axis non-orthogonality (cross-axis sensitivity).
    • Installation/Alignment: The misalignment angles between the FOG axes, accelerometer axes, and the carrier body.
    Show more

    Improving the calibration process of inertial measurement ...


    The Institute of Navigation
    https://navi.ion.org › content
    The Institute of Navigation
    https://navi.ion.org › content
    by H Rahimi · 2020 · Cited by 7 — In this paper, a systematic method for calibration of an inertial measurement unit ( IMU ) for marine applications is proposed which is not based on the accuracy. Read more
    Missing: techniques ‎| Show results with: techniques

    Measurement Error and Calibration of FOG IMU


    Medium · Ericco Inertial Technology
    1 year ago
    Medium · Ericco Inertial Technology
    1 year ago
    Traditional IMU calibration methods include static multi-position calibration under normal temperature environment, angular rate calibration and ... Read more

    IMU calibration method and calibration process


    Ericco Inertial Technology
    https://www.ericcointernational.com › application › imu...
    Ericco Inertial Technology
    https://www.ericcointernational.com › application › imu...
    Apr 10, 2024 — The calibration methods of IMU are mainly divided into two categories: static calibration and dynamic calibration . Static calibration is mainly ... Read more
    5.0 (820)
    Missing: techniques ‎| Show results with: techniques

    A novel hybrid calibration method for FOG-based IMU


    ScienceDirect.com
    https://www.sciencedirect.com › article › abs › pii
    ScienceDirect.com
    https://www.sciencedirect.com › article › abs › pii
    by B Xu · 2019 · Cited by 22 — Combination method of coarse and accurate calibration is used to realize high precision calibration of FOG - IMU sensors. First of all, the system parameters ... Read more

    A time asynchronous parameters calibration method ...


    IOPscience
    https://iopscience.iop.org › article
    IOPscience
    https://iopscience.iop.org › article
    by J Chang · 2023 · Cited by 6 — A single-axis continuous rotation scheme is developed to calibrate the time asynchronous parameters. In particular, a simple observability analysis model is ... Read more

    An Autonomous Calibration for IMUs Using Sensor ...


    White Rose Research Online
    https://eprints.whiterose.ac.uk › eprint
    White Rose Research Online
    https://eprints.whiterose.ac.uk › eprint
    PDF
    by MM Alabdullah · 2024 — IMUs are prone to various deterministic errors, which can be mitigated by adjusting parameters such as the sensor axis misalignment, offsets, inaccurate scale ...

    A Complete Guide to Inertial Measurement Unit (IMU)


    JOUAV
    https://www.jouav.com › blog › inertial-measurement-u...
    JOUAV
    https://www.jouav.com › blog › inertial-measurement-u...
    Apr 17, 2025 — IMUs with magnetometers typically require calibration on the vehicle or in situ to compensate for static magnetic interference that may ... Read more

    A direct approach for high-quality MEMS based IMU/INS ...


    SBG Systems
    https://www.sbg-systems.com › uploads › SBG-A...
    SBG Systems
    https://www.sbg-systems.com › uploads › SBG-A...
    PDF
    by L Poletti · Cited by 4 — The production process starts with the assembling of raw material to get IMUs . Then, each. IMU is calibrated on a temperature controlled double axes rate table. Read more
    19 pages

    A New Calibration Method of MEMS IMU Plus FOG IMU


    ResearchGate
    https://www.researchgate.net › ... › Calibration
    ResearchGate
    https://www.researchgate.net › ... › Calibration
    Aug 17, 2025 — In this paper, we propose a new calibration method based on MEMS IMU with the assistance of the FOG IMU . Different from the traditional MEMS IMU ... Read more

    Understanding Inertial Measurement Unit (IMU)


    GuideNav
    https://guidenav.com › blog › understanding-inertial-m...
    GuideNav
    https://guidenav.com › blog › understanding-inertial-m...
    IMU calibration typically involves three primary sensor systems: the accelerometer, gyroscope, and magnetometer. Each of these sensors requires specific ...

    Scholarly articles for calibration techniques for fog imus

    A novel hybrid calibration method for FOG -based IMU - ‎ Xu - Cited by 22
    … of different grade IMUs for diagnosis applications in … - ‎ Otegui - Cited by 18

    Page Navigation

    1 2 3 4 5 6 7 8 9 10 Next

    Footer Links

    District of Columbia
    - Based on your past activity
    -
    Update location
    Can't update your location
    Learn more
    Updating location...
    Help Send feedback Privacy Terms
    Google apps