The Vivolight LumenCross® F2 is a high-resolution, low-profile (2.67 Fr) intravascular OCT imaging catheter designed for precise coronary artery, lesion, and stent evaluation during percutaneous coronary interventions (PCI). It features enhanced maneuverability for complex cases, a 20mm lens-to-tip distance, and supports Angiographic Co-registration (ACR).
Key Features of the LumenCross F2 Catheter
- High-Resolution Imaging: Provides superior visualization of vessel walls and plaque morphology for accurate stent deployment.
- Low Profile: The 2.67 Fr diameter facilitates easy navigation through tight and complex coronary lesions.
- Optimized Design: Features a short, 20 mm distance from the lens to the tip, allowing for detailed imaging in distal vessel segments.
- Enhanced Deliverability: Engineered for excellent tracking and maneuverability in tortuous coronary anatomy.
- System Compatibility: Fully compatible with angiography co-registration (ACR) to enhance workflow efficiency and reduce contrast use.
- Protective Structure: Special design to protect the imaging lens during delivery to the target site.
Clinical Applications
The F2 catheter is used to guide PCI by providing real-time imaging for:
The F2 catheter is used to guide PCI by providing real-time imaging for:
LumenCross F2 vs. Other Technologies
While standard OCT systems (like those from Abbott) use a 2.7F or larger profiles, the LumenCross F2 (2.67 Fr) focuses on delivering high-resolution imaging with enhanced crossability. It serves as a specialized tool within the growing field of high-frequency, high-resolution intravascular imaging.
While standard OCT systems (like those from Abbott) use a 2.7F or larger profiles, the LumenCross F2 (2.67 Fr) focuses on delivering high-resolution imaging with enhanced crossability. It serves as a specialized tool within the growing field of high-frequency, high-resolution intravascular imaging.
Show more
Web results
OCT Imaging Catheter: LumenCross F2
Vivolight
https://www.vivolight.com › LumenCross F2
Vivolight
https://www.vivolight.com › LumenCross F2
High-Resolution Imaging: Offers exceptional clarity of the vessel wall and lumen, supporting accurate lesion assessment and treatment planning. Excellent Lesion ...Read more
High-Frequency Optical Coherence Tomography - PMC - NIH
PubMed Central (PMC) (.gov)
https://pmc.ncbi.nlm.nih.gov › articles › PMC11993861
PubMed Central (PMC) (.gov)
https://pmc.ncbi.nlm.nih.gov › articles › PMC11993861
by BC Case2025 — In these situations, >1 imaging pullback is usually necessary for a complete vessel assessment, adding time and contrast to the procedure.Read more
Optical Coherence Tomography (OCT) Intravascular Imaging
Cardiovascular.Abbott
https://www.cardiovascular.abbott › hcp › products › o...
Cardiovascular.Abbott
https://www.cardiovascular.abbott › hcp › products › o...
OCT is an intravascular imaging modality that uses near-infrared light to provide high-definition, cross-sectional and three-dimensional images of the vessel ...Read more
Intravascular OCT Imaging System
Vivolight
https://www.vivolight.com › category › intravascular-o...
Vivolight
https://www.vivolight.com › category › intravascular-o...
High-Resolution Imaging: Offers exceptional clarity of the vessel wall and lumen, supporting accurate lesion assessment and treatment planning. Excellent Lesion ...Read more
High resolution in vivo intra-arterial imaging with optical ...
University of Illinois Urbana-Champaign
https://mail.biophotonics.web.illinois.edu › files
University of Illinois Urbana-Champaign
https://mail.biophotonics.web.illinois.edu › files
PDF
by JG Fujimoto1999Cited by 478 — The high resolution of OCT allows imaging to be performed near the resolution of histo- pathology, oVering the potential to have an impact both on the ...Read more
People also ask
Web results
High-resolution intravascular imaging in neurointervention
NeuroNews International
https://neuronewsinternational.com › News
NeuroNews International
https://neuronewsinternational.com › News
Sep 30, 2020 — High-frequency optical coherence imaging can guide neurointerventional surgery to achieve optimal deployment of flow diverters, ...
Optical Coherence Tomography (OCT) | DAIC
Diagnostic and Interventional Cardiology
https://www.dicardiology.com › channel › optical-cohere...
Diagnostic and Interventional Cardiology
https://www.dicardiology.com › channel › optical-cohere...
Optical coherence tomography (OCT) is an catheter-based intravascular imaging technology that uses low-coherence light interferometry, using near-infrared ...
OPTICROSS™ HD Coronary Imaging Catheters
www.bostonscientific.com
https://www.bostonscientific.com › products › opticross...
www.bostonscientific.com
https://www.bostonscientific.com › products › opticross...
The OPTICROSS HD Imaging Catheter has comparable resolution, low contrast usage, and better depth than Abbott's optical coherence tomography (OCT).Read more
Optical Coherence Tomography (OCT) Eyal Ben-Assa MD, ...
American College of Cardiology
https://www.acc.org › media › Chapter-13_OCT
American College of Cardiology
https://www.acc.org › media › Chapter-13_OCT
PDF
by E Ben-Assa — Step-by-step guide to performing OCT. OCT intravascular imaging allows a fast acquisition of a high-resolution image that can immediately aid the operator ...Read more
The benefits of optical coherence tomography in the cath lab
Cardiovascular News
https://cardiovascularnews.com › News
Cardiovascular News
https://cardiovascularnews.com › News
by K Croce — OCT-guided percutaneous coronary intervention (PCI) results in greater stent expansion, less residual stenosis, and a better residual fractional flow reserve ( ...Read more
Scholarly articles for High-Resolution Intravascular OCT Catheter F2 | |
… design for endoscopic optical coherence tomography - Lee - Cited by 5 … plaque in vivo using optical coherence tomography … - Lee - Cited by 62 … optical coherence tomography and frequency-domain … - Chen - Cited by 22 | |