Skip to main contentAccessibility help
Accessibility feedback
Press / to jump to the search box
Choose what you’re giving feedback on
  • Delete

  • See more
  • Delete

  • See more
  • Report inappropriate predictions
    Quick Settings
    Sign in
    AI Mode
    All
    Images
    Shopping
    Videos
    Short videos
    Forums
    More
    Web
    News
    Books
    Maps
    Tools

    Search Results

    Any time
    Any time
    Past hour
    Past 24 hours
    Past week
    Past month
    Past year
    Custom range...
    Custom date range
    Go
    All results
    All results
    Verbatim
    Advanced Search
    About 123 results (0.20s) 
    Ctrl+Shift+X to select
    An AI Overview is not available for this searchCan't generate an AI overview right now. Try again later.
    AI Overview
    Distal medial tibial fracture plates are specialized orthopedic implants designed for the surgical fixation of distal tibia (pilon) fractures, particularly for medial split depression injuries, often utilizing a minimally invasive approach (MIPO) to reduce soft tissue injury. These low-profile, often titanium or stainless steel, plates are anatomically pre-contoured to fit the tibia and are frequently paired with locking screws to provide stable, rigid fixation. 
    Key Features and Benefits 
    • Anatomic Design: Plates feature a low-profile design to manage the limited soft tissue coverage on the distal medial tibia.
    • Minimally Invasive Option: They are well-suited for MIPO, which can result in fewer complications, reduced infection risk, and faster functional recovery compared to traditional open methods.
    • Versatile Fixation: Options often include 2.7 mm, 3.5 mm, or 4.5 mm locking and non-locking screws to manage different bone qualities and fracture types, including those extending into the shaft.
    • Specific Designs: Some systems include specialized distal tabs for enhanced stability and screw options to address specific articular fragments. 
    Indications and Application 
    • Indicated for: Distal tibia fractures, including extra-articular and simple intra-articular fractures.
    • Approach: A direct medial approach or percutaneous insertion is often used to minimize tissue trauma. 
    Common Manufacturers & Systems 
    • Arthrex Distal Tibia Plating System
    • Unite Foot and Ankle Medial Distal Tibia Plates
    • DePuy Synthes LCP Medial Distal Tibia Plate 
    Clinical Considerations 
    • Complications: Risks include soft tissue irritation, superficial wound infection, and potential for symptomatic hardware, often requiring removal.
    • Recovery: While MIPO improves outcomes, return to normal activity can take up to 6 months, with full sporting recovery sometimes taking 12 months, requiring a gradual return to full weight-bearing. 
    • Distal Tibia Plating System - Arthrex
      The Arthrex Distal Tibia Plating System was designed for the versatile treatment of distal tibia fractures.• Includes anterolatera...
      www.arthrex.com
    • Soft tissue complications in distal tibial fractures managed with medial ...
      Complications associated with medial locked plating include superficial and deep wound infection (both early and delayed), promine...
      pmc.ncbi.nlm.nih.gov
    • Results and complications of minimally invasive medial plate ... - PMC
      Conclusion. Minimally invasive medial plate osteosynthesis for the distal metaphyseal tibial fracture is safe and effective. This ...
      pmc.ncbi.nlm.nih.gov
    Show all
    • Distal Tibia Plating System - Arthrex
      The Arthrex Distal Tibia Plating System was designed for the versatile treatment of distal tibia fractures.• Includes anterolatera...
      www.arthrex.com
    • Soft tissue complications in distal tibial fractures managed with medial ...
      Complications associated with medial locked plating include superficial and deep wound infection (both early and delayed), promine...
      pmc.ncbi.nlm.nih.gov
    • Results and complications of minimally invasive medial plate ... - PMC
      Conclusion. Minimally invasive medial plate osteosynthesis for the distal metaphyseal tibial fracture is safe and effective. This ...
      pmc.ncbi.nlm.nih.gov
    • Medial approach to the distal tibia - AO Surgery Reference
      A direct medial approach can be used for vertical medial split depression fractures with associated articular impaction.
      surgeryreference.aofoundation.org
    • Minimally Invasive Plate Osteosynthesis with Locking ... - PMC
      MIPO with locking plates for distal tibia fractures is associated with good functional outcomes and is an effective treatment for ...
      pmc.ncbi.nlm.nih.gov
    • Distal tibia fractures and medial plating: factors influencing re- ... - PMC
      Conclusions. There was a high re-operation rate associated with distal tibia medial plating, with significant differences in the r...
      pmc.ncbi.nlm.nih.gov
    • Internal Fixation for Distal Tibia Fracture/Pilon - Arthrex
      The distal tibia plates are made of stainless steel and are an extension of the ankle fracture management system. Plates have been...
      www.arthrex.com
    • Medial Distal Tibia Plates - Unite Foot and Ankle
      Medial Distal Tibia plates feature a distal tab with a machined relief on the underside of the plate to allow for bending and cont...
      medlineunite.com
    • Distal Medial Tibial Locking Plate,Medical Device Manufacturers
      This information does not constitute medical advice or diagnosis. A distal medial tibial locking plate is a solution for: * Extra-
      www.doublemedicalgp.com
    • LCP Medial Distal Tibia Plate, without Tab. The Low Profile ...
      Fixation with the LCP Medial Distal Tibia Plate without Tab has many similarities to traditional plate fixation methods, with a fe...
      www.rch.org.au
    • Posterolateral Distal Tibia Plates - Unite Foot and Ankle
      Posterolateral Distal Tibia plates are designed for severely comminuted fractures requiring a posterior approach. The plates featu...
      medlineunite.com
    • Tibial Plateau Fracture Treatment - Exercises, FAQs & Case
      If the fractured bones shifted after the break and surgery was required to put the bones together with pins and plates, then it ca...
      motionptr.com
    • Physiotherapy after tibial plateau fracture fixation - PMC - NIH
      This can vary from immediate weight bearing as pain allows after internal fixation, to partial weight bearing for 6–12 weeks and n...
      pmc.ncbi.nlm.nih.gov
    This is for informational purposes only. For medical advice or diagnosis, consult a professional. AI responses may include mistakes. Learn more
    Share
    Facebook
    WhatsApp
    X
    Email
    Click to copy link
    Share link
    Link copied
    Thank you
    Your feedback helps Google improve. See our Privacy Policy.
    Share more feedback
    Report a problem
    Close
    Thank you
    Your feedback helps Google improve. See our Privacy Policy.
    Share more feedback
    Report a problem
    Close
    Thank you
    Your feedback helps Google improve. See our Privacy Policy.
    Share more feedback
    Report a problem
    Close
    Show more
    My Ad Center

    Web results

    Distal Tibia Plating System


    Arthrex
    https://www.arthrex.com › foot-ankle › distal-tibia-plati...
    Arthrex
    https://www.arthrex.com › foot-ankle › distal-tibia-plati...
    The Arthrex Distal Tibia Plating System was designed for the versatile treatment of distal tibia fractures.• Includes anterolateral, medial, anterior, ...
    Distal Medial Tibial Fracture Plate from www.arthrex.com

    Medial approach to the distal tibia - AO Surgery Reference


    AO Foundation Surgery Reference
    https://surgeryreference.aofoundation.org › adult-trauma
    AO Foundation Surgery Reference
    https://surgeryreference.aofoundation.org › adult-trauma
    A direct medial approach can be used for vertical medial split depression fractures with associated articular impaction.Read more
    Distal Medial Tibial Fracture Plate from surgeryreference.aofoundation.org

    Medial Distal Tibia Plates - Unite Foot and Ankle


    Medline UNITE
    https://medlineunite.com › Products
    Medline UNITE
    https://medlineunite.com › Products
    Medial Distal Tibia plates feature a distal tab with a machined relief on the underside of the plate to allow for bending and contouring to adapt to anatomical ...Read more
    Distal Medial Tibial Fracture Plate from medlineunite.com

    Minimally Invasive Plate Osteosynthesis with Locking ... - PMC


    National Institutes of Health (.gov)
    https://pmc.ncbi.nlm.nih.gov › articles › PMC4843339
    National Institutes of Health (.gov)
    https://pmc.ncbi.nlm.nih.gov › articles › PMC4843339
    by A Dhakar · 2016 · Cited by 28 — MIPO with locking plates for distal tibia fractures is associated with good functional outcomes and is an effective treatment for distal tibia fractures.Read more

    LCP Medial Distal Tibia Plate, without Tab. The Low ...


    The Royal Children's Hospital
    https://www.rch.org.au › main › content › ortho
    The Royal Children's Hospital
    https://www.rch.org.au › main › content › ortho
    PDF
    Fixation with the LCP Medial Distal Tibia Plate without Tab has many similarities to traditional plate fixation methods, with a few important improvements.Read more
    Distal Medial Tibial Fracture Plate from www.rch.org.au
    Videos
    Anterolateral Distal Tibia Plate
    YouTube · What's New in Orthopedics
    May 20, 2021
    YouTube · What's New in Orthopedics
    2:47
    Place a 3.5 millimeter cortical screw in the oblong hole proximal to the fracture. This will temporarily secure the plate to the tibia.
    Distal Tibia Fracture | Distal Tibia Medial Locking Plate
    YouTube · Ortho Implants For Life
    Jan 7, 2021
    YouTube · Ortho Implants For Life
    13:10
    Today we will discuss about digital tbr fracture physician procedure and implants instrumentations involved in the process.
    Medial Distal Tibia Plate- Distal Tibia Anatomical Locked Plate
    YouTube · SHARMA ORTHOPEDIC
    Dec 3, 2015
    YouTube · SHARMA ORTHOPEDIC
    14:38

    View all

    Web results

    A.L.P.S.® Distal Tibia Plating Systems


    Zimmer Biomet
    https://www.zimmerbiomet.com › foot-and-ankle › alps-...
    Zimmer Biomet
    https://www.zimmerbiomet.com › foot-and-ankle › alps-...
    The plate's design allows it to sit tightly next to the distal ridge of the tibia and provide strong fixation in comminuted fractures or osteoporotic bone.Read more
    Distal Medial Tibial Fracture Plate from www.zimmerbiomet.com
    Images
    MIO - Compression plate for Extraarticular, simple fracture
    MIO - Compression plate for Extraarticular, simple fracture
    AO Surgery Reference - AO Foundation
    Medial Distal Tibia Plates - Unite Foot and Ankle
    Medial Distal Tibia Plates - Unite Foot and Ankle
    Medline UNITE
    LCP Medial Distal Tibia Plate w/o tab 3.5
    LCP Medial Distal Tibia Plate w/o tab 3.5
    AO Foundation
    Distal Medial Tibial Locking Plate,Medical Device ...
    Distal Medial Tibial Locking Plate,Medical Device ...
    Double Medical
    Arthrex - Internal Fixation for Distal Tibia Fracture/Pilon
    Arthrex - Internal Fixation for Distal Tibia Fracture/Pilon
    Arthrex
    Medial Distal Tibia Plates - Unite Foot and Ankle
    Medial Distal Tibia Plates - Unite Foot and Ankle
    Medline UNITE
    Medial versus lateral plating in distal tibial fractures: A ...
    Medial versus lateral plating in distal tibial fractures: A ...
    Elsevier
    LCP Medial Distal Tibia Plate w/o tab 3.5
    LCP Medial Distal Tibia Plate w/o tab 3.5
    AO Foundation
    The photograph of the plates used in this study. A, LCP ...
    The photograph of the plates used in this study. A, LCP ...
    ResearchGate

    All images

    Show more images
    People also ask
    What is the recovery time for tibia plate surgery?
    If the fractured bones shifted after the break and surgery was required to put the bones together with pins and plates, then it can take up to 6 months to walk normal and 12 months to return to playing sports like before the injury.

    Tibial Plateau Fracture Treatment - Exercises, FAQs & Case


    Motion Physical Therapy & Rehab
    https://motionptr.com › blog › tibial-plateau-fracture-w-...
    Motion Physical Therapy & Rehab
    https://motionptr.com › blog › tibial-plateau-fracture-w-...
    What is the recovery like after distal tibia plating?
    Most people with a tibial plateau fracture recover well. You're comfortable by about six weeks after surgery. It takes up to four months before we clear you for full activity. Take your recovery seriously; bones that heal unevenly can lead to pain, stiffness, and arthritis.May 2, 2025

    Tibial Plateau Fracture Treatment: What to Expect


    Austin Foot & Ankle Institute
    https://www.drfootandankle.com › post › tibial-plateau-f...
    Austin Foot & Ankle Institute
    https://www.drfootandankle.com › post › tibial-plateau-f...
    Can I walk after tibia plating?
    This can vary from immediate weight bearing as pain allows after internal fixation, to partial weight bearing for 6–12 weeks and non-weight bearing from 4 to 12 weeks. These states progress gradually to full weight bearing after the above-mentioned periods of time.

    Physiotherapy after tibial plateau fracture fixation - PMC - NIH


    PMC - NIH
    https://pmc.ncbi.nlm.nih.gov › articles › PMC7576901
    PMC - NIH
    https://pmc.ncbi.nlm.nih.gov › articles › PMC7576901
    What is the success rate of distal tibia plating?
    Surgical site infection (6.7%) and malunion (3.3%) were the main complications. Functional outcomes: Excellent in 30%, Good in 40%, Fair in 20%, Poor in 10%. Conclusion: Locking plate osteosynthesis for distal tibia fractures yields satisfactory union rates and functional recovery with acceptable complication profiles.Jul 4, 2025

    Outcomes of Distal Tibia Fractures Treated with Plate Osteosynthesis


    The Journal of Contemporary Clinical Practice
    https://jccpractice.com › article › outcomes-of-distal-tibia...
    The Journal of Contemporary Clinical Practice
    https://jccpractice.com › article › outcomes-of-distal-tibia...

    Web results

    MIO - Compression plate for Extraarticular, simple fracture


    AO Foundation Surgery Reference
    https://surgeryreference.aofoundation.org › distal-tibia
    AO Foundation Surgery Reference
    https://surgeryreference.aofoundation.org › distal-tibia
    The most distal 8-12 cm of the plate must be bent to form a concave arc with a radius of curvature of about 20 cm and twisted to fit the distal tibia. As ...Read more

    Distal Medial Tibial Locking Plate - Double Medical


    Double Medical
    https://www.doublemedicalgp.com › Plate
    Double Medical
    https://www.doublemedicalgp.com › Plate
    The anatomical precontoured plate is specially designed to fit the complex shape of the distal part of the bone, assisting reduction of metaphysis to diaphysis ...Read more
    Distal Medial Tibial Fracture Plate from www.doublemedicalgp.com
    People also search for
    Medial Distal Tibia Plate
    Medial Distal Tibia Plate Synthes
    Distal tibia medial plate approach
    Anterolateral Distal Tibia Plate
    Distal tibia fracture
    Distal tibia Anatomical plate
    Anteromedial distal tibia Plate
    Arthrex distal tibia plates

    Page Navigation

    12345678910Next

    Footer Links

    Sacramento-Stockton-Modesto CA, California
     - Based on your past activity
     - 
    Update location
    Can't update your location
    Learn more
    Updating location...
    HelpSend feedbackPrivacyTerms
    Google apps