Computing server water chillers are
specialized cooling systems designed to remove high-density heat from IT equipment, utilizing water's superior thermal conductivity to maintain optimal operating temperatures, especially for AI and high-performance computing (HPC) workloads. These systems, which can be part of large-scale facility infrastructure or compact "in-row" units, often achieve better energy efficiency (lower PUE) than traditional air-cooled methods, according to Lenovo and Supermicro.Types of Server Water Chillers & Cooling Systems
- Chilled Water Systems (CRAH): Computer Room Air Handlers (CRAHs) use a central chiller to provide cold water to air handlers, which then cool the room air.
- In-Row Chilled Water Cooling: Close-coupled units, such as APC InRow, are placed directly between server racks to capture hot exhaust air and provide efficient, localized cooling.
- Direct-to-Chip (DLC) Liquid Cooling: Cold plates are attached directly to high-heat components like CPUs and GPUs, with water circulating to remove heat before it enters the air, reducing cooling energy by up to 40%.
- Rear Door Heat Exchangers (RDHx): A liquid-cooled heat exchanger is installed on the rear of the server rack, capturing heat from the hot exhaust air.
- Immersion Cooling: Servers are submerged in a thermally conductive, non-conductive dielectric fluid, allowing for massive heat reduction.
Key Components and Features
- Coolant Distribution Units (CDUs): These provide temperature and flow rate control for the secondary cooling loop, often using a liquid-to-liquid heat exchanger to move heat from the racks to the facility water loop.
- Leak Detection & Monitoring: Advanced systems include sensors to notify users of potential water leaks within the cooling unit.
- Titanium Heat Exchangers: Used in high-quality, corrosion-resistant chillers (e.g., Hailea).
- Variable Speed Fans/Pumps: These optimize power usage by adjusting to the cooling load.
Benefits of Water Cooling
- Improved Efficiency: Liquid-cooled systems can reduce power costs by up to 40% compared to traditional air cooling.
- Higher Density: Enables higher rack densities (over 20 kW), which is necessary for AI hardware that can exceed 1,200 watts per GPU.
- Performance Stability: Prevents thermal throttling in CPUs and GPUs.
- Sustainability: Allows higher water temperatures, reducing the need for mechanical refrigeration ("free cooling").
Key Manufacturers and Solutions
- APC by Schneider Electric: InRow Chilled Water Cooling.
- Vertiv: Liebert® AFC high-capacity inverter screw chiller.
- CoolIT Systems: Direct Liquid Cooling (DLC) for HPC and AI.
- Boyd: High-capacity, customizable liquid cooling systems.
- S&A Teyu: Industrial water chillers (e.g., CW-7800).
- Submer: Immersion cooling technology.
These systems are increasingly necessary as AI chip power reaches 1,200 watts, with some projections going up to 5,000 watts, making traditional air cooling incapable of handling the heat.
Show all
Show more
CoolIT Systems: Cooling Solutions for HPC, AI & Data Centers
CoolIT Systems
https://www.coolitsystems.com
CoolIT Systems
https://www.coolitsystems.com
Engineered for tomorrow's workloads, CoolIT liquid cooling powers HPC, AI, and enterprise systems with efficient CDUs, cold plates and heat exchangers.
Server Chillers » Powerful Water Cooling ...
Aquatuning
https://www.aquatuning.com › server-chiller
Aquatuning
https://www.aquatuning.com › server-chiller
Discover powerful server chillers for water cooling systems ➤ Premium quality ✓ Fast delivery ✓ Competitive prices ✓ Shop online now!
€334 to €1,386$50 delivery30-day returns
SERVER CHILLER & COOLING TO MAINTAIN IDEAL ...
Cold Shot Chillers
https://waterchillers.com › blog › server-chiller-and-coo...
Cold Shot Chillers
https://waterchillers.com › blog › server-chiller-and-coo...
Jun 21, 2021 — Generally, a server chiller works by incorporating raised floors with computer room air conditioners (CRAC) or computer room air handlers (CRAH) ...Read more
Liquid Cooled AI Workstation PC and Servers - Bizon-tech
bizon-tech.com
https://bizon-tech.com › liquid-cooled-workstation-comp...
bizon-tech.com
https://bizon-tech.com › liquid-cooled-workstation-comp...
Our water-cooled technology ensures that your system runs smoothly, up to 3x times lower noise, even under heavy load and 24/7 operation. The design of each ...Read more
Free delivery30-day returns
Liquid cooling options for data centers
Vertiv
https://www.vertiv.com › en-us › solutions › learn-about
Vertiv
https://www.vertiv.com › en-us › solutions › learn-about
Learn about the future of data center cooling and how liquid cooling solutions support high-density computing and enhance performance and energy efficiency.
Rack-Scale Liquid Cooling Solutions
Supermicro
https://www.supermicro.com › solutions › liquid-cooling
Supermicro
https://www.supermicro.com › solutions › liquid-cooling
Dive into Liquid Cooling Server solutions, providing efficient thermal management. Ideal for high-performance computing, ensuring optimal operation.
Air-cooled water chiller for water-cooled computing server
TEYU Chiller
https://www.teyuchiller.com › S&A Blog
TEYU Chiller
https://www.teyuchiller.com › S&A Blog
S&A Teyu CW-7800 is high-precision compression refrigeration water chiller,with intelligent temperature control,completed configuration,perfect protection and ...Read more
Diving Deep into the Liquid Server Cooling Choices
Dell
https://www.dell.com › Home › Blog
Dell
https://www.dell.com › Home › Blog
May 3, 2024 — As noted above, deploying IT in an enclosure with an in-row cooler permits warmer water to be used, and this brings a 19% energy savings over ...Read more
Liquid Cooling | Center of Expertise for Data Center Efficiency
Lawrence Berkeley National Laboratory (.gov)
https://datacenters.lbl.gov › liquid-cooling
Lawrence Berkeley National Laboratory (.gov)
https://datacenters.lbl.gov › liquid-cooling
During operation, hot server-rack exhaust air is forced through the device by the server fans. Heat is exchanged from the hot air to circulating cold water from ...Read more